Moxa TCF-142-S-ST-RM
TCF-142-S-ST-RM
TCF-142-RM Series
RS-232/422/485 to single-mode fiber slide-in module converter, ST connector
Serial Interface
No. of Ports
- 2
Serial Standards
- RS-232, RS-422, RS-485
Baudrate
- 50 bps to 921.6 kbps (supports non-standard baudrates)
Flow Control
- ADDC® (automatic data direction control) for RS-485
Connector
- Single-mode ST connector
Optical Fiber
Optical Fiber
Low-Speed Fiber Module Multi-Mode Single-Mode Fiber Cable Requirements 50/125 µm, 800 MHz G.652 62.5/125 µm, 500 MHz Typical Distance 5 km 40 km Wavelength Typical (nm) 850 1310 TX Range (nm) 840 to 860 1290 to 1330 RX Range (nm) 800 to 900 1100 to 1650 Optical Power TX Range (dBm) 0 to -5 0 to -5 RX Range (dBm) 0 to -20 0 to -25 Link Budget (dB) 15 20 Dispersion Penalty (dB) 1 1 Note: When using a power meter to measure the fiber TX power, set the baudrate to 9,600 bps and send data (00, ..., 0h) to the serial converter?s serial port.
Pull High/Low Resistor for RS-485
- 1 kilo-ohm, 150 kilo-ohms
RS-485 Data Direction Control
- ADDC® (automatic data direction control)
Terminator for RS-485
- N/A, 120 ohms, 120 kilo-ohms
Serial Signals
RS-232
- TxD, RxD, GND
RS-422
- Tx+, Tx-, Rx+, Rx-, GND
RS-485-4w
- Tx+, Tx-, Rx+, Rx-, GND
RS-485-2w
- Data+, Data-, GND
Power Parameters
Input Current
- 150 mA @ 12 VDC
Overload Current Protection
- Supported
Power Consumption
- 150 mA @ 12 VDC
Physical Characteristics
Housing
- Metal
IP Rating
- IP30
Dimensions
- 86.8 x 136.5 x 21 mm (3.42 x 5.37 x 0.83 in)
Weight
- 105 g (0.23 lb)
Environmental Limits
Operating Temperature
- 0 to 60°C (32 to 140°F)
Storage Temperature (package included)
- -20 to 75°C (-4 to 167°F)
Ambient Relative Humidity
- 5 to 95% (non-condensing)
Standards and Certifications
EMC
- EN 55032/24
EMI
- CISPR 32, FCC Part 15B Class A
EMS
- IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m
IEC 61000-4-4 EFT: Power: 1 kV; Signal: 0.5 kV
IEC 61000-4-5 Surge: Power: 1 kV; Signal: 0.5 kV
IEC 61000-4-6 CS: 150 kHz to 80 MHz: 3 V/m; Signal: 3 V/m
IEC 61000-4-8 PFMF
- IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV
Environmental Testing
- IEC 60068-2-1
IEC 60068-2-2
IEC 60068-2-3
- IEC 60068-2-1
Safety
- EN 60950-1, IEC 60950-1
Vibration
- IEC 60068-2-6
MTBF
Time
- 514,926 hrs
Standards
- Telcordia (Bellcore), GB
Warranty
Warranty Period
- 5 years
Details